Electric bus defroster
NFDCS-900B-WX033
Quantity:
Technical requirement:
1. fan voltage: DC24V, power: 180W; (purchased fan)
2. the voltage of the heater is 600V (ensure normal operation between 450v-750v), and the power of the heater is
4kw; Equipped with 90 ° normally closed temperature switch;
3. plastic sprayed black and matte; The length of outgoing line outside the shell is 300mm-400mm;
4. the model of high voltage socket is pl082x-61-4, with positive pole at position 1 and negative pole at position 2;
(model of plug-in end: pl182x-61-4); The high-pressure port is blocked with a special protective cover;
5. all air outlets of the defroster shall be blocked with adhesive tape to prevent dust from entering;
6. supporting dcs-k2-wx001; The connecting harness is provided with the machine (see the attached figure);
7. built in high-voltage contactor;
8. Self tapping screws shall not be used for assembly and fixation